manual for napoleon gas fireplace

Safety Information

Always follow safety guidelines to ensure safe operation. If you smell gas, do not light appliances or use electrical devices. Immediately evacuate and contact your gas supplier or fire department. Installation must be performed by a qualified installer to meet local codes and safety standards. Never leave children or vulnerable individuals unattended near the appliance. Keep combustible materials away from the fireplace. Regular maintenance is essential to prevent hazards and ensure optimal performance. Refer to the manual for detailed safety precautions and warranty information.

1.1. Emergency Procedures

Do not attempt to light any appliance or touch electrical switches if you smell gas. Immediately evacuate the area and contact your gas supplier from a neighbor’s phone. If the supplier is unreachable, call the fire department. Follow all instructions provided by these authorities. Installation and servicing must be performed by a qualified professional to ensure safety and compliance with local codes. Never leave children or vulnerable individuals unattended near the fireplace. Keep the appliance and surrounding area clear of combustible materials. Regular maintenance by a certified technician is essential to prevent potential hazards.

1.2. Installation Requirements

Installation must be conducted by a qualified installer, adhering to local codes and manufacturer guidelines. Ensure the fireplace is vented using Napoleon-approved kits to maintain safety and efficiency. The appliance must not be installed in confined spaces without proper ventilation provisions. Finish enclosure walls with materials like drywall to prevent insulation contact and ensure clearance to combustibles. Proper reinstallation and sealing are necessary after servicing. Follow all specifications outlined in the manual to avoid potential hazards and ensure compliance with national standards like CSA 22.2 NO. 46 and UL 2021. Always refer to the manual for detailed installation instructions.

1.3. General Safety Precautions

Always maintain a safe distance from the fireplace when it is in operation, as surfaces can become extremely hot. Never touch the glass or metal components during or immediately after use. Keep children and pets away from the appliance while it is burning. Ensure proper ventilation in the room to prevent carbon monoxide buildup. Do not leave the fireplace unattended while lit. If you notice any damage or malfunction, discontinue use and contact a qualified technician. Regular inspections by a certified professional are essential to ensure safe operation. Follow all safety guidelines outlined in the manual to protect yourself and others from potential hazards.

Installation Instructions

Installation must be performed by a qualified installer following local codes. Ensure proper ventilation and combustion air provisions. Follow specific procedures for peninsula, open-end, see-through, or island installations. Use Napoleon vent kits for safe venting. Proper framing and wall finishing are essential to maintain clearances and avoid exposure to insulation or vapor barriers. Adhere to all guidelines to ensure a safe and efficient setup.

2.1. Combustion and Ventilation Air Provisions

Adequate combustion and ventilation air is crucial for safe operation; This heater must not be installed in confined spaces without proper provisions for combustion air. Ensure the enclosure walls are finished (e.g., drywall) to prevent insulation or vapor barriers from contacting the fireplace. Proper ventilation ensures efficient burning and prevents carbon monoxide buildup. Follow local codes and manufacturer guidelines for venting specifications. Incorrect installation can lead to safety hazards and reduced performance. Always use Napoleon-approved vent kits and maintain clearances to combustible materials as specified in the manual.

2.2. Gas Installation

Gas installation must be performed by a qualified installer, service agency, or supplier to ensure compliance with local codes and safety standards. The gas supply line should be properly sized and installed according to the manufacturer’s specifications. Ensure the gas piping is leak-free and meets all regulatory requirements. Do not use the fireplace if you detect a gas leak. Always follow the gas supplier’s instructions for emergencies. Proper installation ensures safe and efficient operation, complying with national standards like CSA and UL certifications. Refer to the manual for detailed gas connection procedures and guidelines.

2.3. Peninsula Installation Procedure

For a peninsula installation, ensure the fireplace enclosure walls are finished with drywall or sheetrock to maintain clearance from combustibles. This prevents exposed insulation or vapor barriers from contacting the fireplace. Framing must provide adequate space for ventilation and combustion air. Follow the manufacturer’s specifications for framing dimensions and clearances. Proper installation ensures safety and efficiency, complying with local building codes. Refer to the manual for detailed steps and diagrams to achieve a secure and correct installation. Always ensure the installation is done by a qualified professional.

2.4. Open-End Installation Procedure

For an open-end installation, finish the enclosure walls with drywall or sheetrock to prevent insulation or vapor barriers from touching the fireplace. Ensure proper framing to maintain clearances and provide adequate ventilation. Follow the manufacturer’s guidelines for framing dimensions and combustion air provisions. This method allows for a realistic flame view while ensuring safety. Always have a qualified installer perform the installation to meet local codes and safety standards. Proper installation is crucial for optimal performance and to prevent potential hazards. Consult the manual for detailed instructions and diagrams specific to this configuration.

2.5. See-Through Installation Procedure

For a see-through installation, ensure the fireplace enclosure walls are finished with drywall or sheetrock to maintain clearances and avoid contact with combustible materials. Proper framing is essential to accommodate the unit’s dimensions. Follow ventilation and combustion air provisions as outlined in the manual. This configuration allows viewing from both sides, enhancing aesthetic appeal. Ensure all electrical connections are made by a qualified installer, adhering to local codes. Regular maintenance is crucial to uphold safety and performance. Refer to the manual for specific instructions and diagrams to ensure a correct and safe installation. Proper setup guarantees years of efficient and enjoyable use.

2.6. Island Installation Procedure

For an island installation, position the fireplace in a central location, ensuring proper framing and clearance from combustible materials. Finish enclosure walls with drywall or sheetrock to prevent insulation contact. Maintain adequate ventilation and combustion air supply as specified. This setup allows unobstructed viewing from all sides, maximizing visual impact. Ensure electrical connections are securely made by a qualified installer, following local codes. Regular maintenance is vital to uphold safety and efficiency. Consult the manual for detailed instructions and diagrams to ensure a correct installation, guaranteeing optimal performance and enjoyment for years to come. Proper installation is key to safety and functionality.

Operating Instructions

Turn the burner on/off using the control knob or remote. Ensure the pilot flame is properly lit and adjust as needed. Monitor for unusual odors or sounds. Always follow the remote control instructions for safe operation. If issues arise, refer to the troubleshooting guide before relighting the fireplace. Regular checks ensure optimal performance and safety;

3.1. Daily Operation

To operate your Napoleon gas fireplace daily, ensure the burner is turned on using the control knob or remote. Always light the pilot flame correctly and adjust the burner as needed. Monitor the flame for proper size and color. If unusual odors or sounds occur, turn off the fireplace and consult the manual. Regular checks of the burner and control compartment are essential for safe and efficient operation. Keep the area clear of combustible materials. After the first use, a slight odor may be present, but it will dissipate. Refer to the manual for specific operation instructions tailored to your model.

3.2. Remote Control Usage

The remote control provides convenient operation of your Napoleon gas fireplace. Use it to turn the fireplace on/off, adjust heat output, and control flame height. Ensure the remote is easily accessible but out of reach of children. Before using the remote, familiarize yourself with its functions as outlined in the manual. Some models may have additional features like timer settings or variable speed control. Always ensure the remote is properly paired with your fireplace for reliable operation. Replace batteries as needed to maintain functionality. Refer to the manual for specific remote control instructions tailored to your fireplace model.

3.3. Troubleshooting Common Issues

Identify and resolve common issues promptly to ensure safe and efficient operation. If the pilot light does not stay lit, check for proper gas flow or obstructions in the pilot tube. For incorrect flame size or color, adjust the air shutter or ensure proper ventilation. If soot appears on glass, clean it regularly and ensure the burner is free of debris. If the fireplace shuts off frequently, check for adequate combustion air or ensure the venting system is clear. Always turn off the gas and electrical power before servicing. Refer to the manual for detailed troubleshooting steps or contact a qualified technician if issues persist.

Maintenance and Care

Regular maintenance ensures optimal performance and safety. Clean glass doors and catalytic tiles to maintain efficiency and appearance. Inspect burners for blockages and ensure proper airflow. Schedule annual professional inspections to address potential issues early. Store logs and embers correctly to preserve their quality. Always turn off gas and power before servicing. Refer to the manual for detailed care instructions to maintain warranty and safety standards.

4.1. Routine Maintenance

Regular maintenance is crucial for optimal performance and safety of your Napoleon gas fireplace. Turn off the gas supply and electrical power before servicing. Inspect the burner and control compartment for cleanliness and obstructions. Ensure the blower and its passageways are free from debris. Clean glass doors and catalytic tiles to maintain heat efficiency and appearance. Inspect logs and glowing embers for wear and tear, replacing them as needed. Schedule an annual professional inspection to ensure all components function properly. Addressing minor issues promptly prevents major repairs and ensures your fireplace operates safely and efficiently throughout the heating season.

4.2. Care of Glass Doors and Catalytic Tiles

Regular cleaning of glass doors and catalytic tiles is essential for maintaining efficiency and appearance. Use a soft cloth and a mild detergent mixed with water to clean glass doors, avoiding abrasive materials that may scratch the surface. For catalytic tiles, ensure they are cool before cleaning, and gently brush off debris with a soft-bristle brush. Avoid using harsh chemicals, as they may damage the tiles. Inspect tiles regularly for cracks or damage and reattach any loose tiles promptly. Replace damaged tiles immediately to maintain proper function and safety. Proper care ensures optimal performance and longevity of your Napoleon gas fireplace.

4.3. Log Placement and Glowing Embers

Proper placement of logs and glowing embers is crucial for a realistic and efficient fire experience. Arrange logs as instructed to ensure even flame distribution and avoid overcrowding. Glowing embers should be placed on the burner’s ported area, tearing them into thin, irregular pieces for maximum glow. Only exposed edges will glow when in contact with direct flames. Position embers carefully to enhance the visual effect. Avoid moving logs or embers while the fireplace is in operation. Follow the manufacturer’s guidelines for the type and quantity of logs and embers to use, ensuring safe and optimal performance of your Napoleon gas fireplace.

Optional Features

Enhance your fireplace experience with optional features like a blower for heat circulation and a catalytic door system for improved safety and efficiency. These upgrades offer convenience and performance, tailored to your needs. Ensure all installations comply with manufacturer guidelines for optimal functionality and safety.

5.1. Blower Installation

The blower installation enhances heat circulation from your Napoleon gas fireplace. It must be installed by a qualified technician to ensure safety and proper function. The blower is thermally activated and starts automatically when the fireplace reaches a certain temperature. It improves heat distribution, making your space cozier. However, it’s not recommended for 4-sided installations. Always follow local electrical codes and manufacturer instructions during installation. Regular maintenance is crucial to keep the blower working efficiently. Ensure it’s properly grounded and connected to avoid any hazards. This feature adds comfort and value to your fireplace experience.

5.2. Catalytic Door System

The catalytic door system is a unique, patented feature designed to enhance safety and performance. It reduces carbon monoxide emissions and provides a secure, efficient burn. When installed, glass doors must be used on all other openings to ensure proper function. Ornamental insets cannot be used with this system. The catalytic door must be installed by a qualified technician to meet safety standards. This system offers peace of mind and improved safety features for your Napoleon gas fireplace. Proper installation ensures optimal performance and safety, making it a valuable addition to your fireplace experience.

Warranty and Support

Napoleon fireplaces are certified to CSA and ANSI standards, ensuring quality and safety. The warranty covers parts and labor under normal conditions. Proper installation by a qualified technician is required for warranty validity. For support, contact Napoleon at 1 (866) 820-8686 or visit their website for assistance and replacement parts information. Regular maintenance by authorized personnel ensures warranty coverage and optimal performance. Refer to the manual for detailed warranty terms and conditions.

6.1. Manufacturer Warranty

Napoleon gas fireplaces are backed by a limited manufacturer warranty covering defects in materials and workmanship; The warranty period varies by component, with burners and valves typically covered for longer durations. Proper installation by a qualified technician is mandatory for warranty validity. Damage from misuse, improper installation, or normal wear and tear is excluded. To file a claim, contact Napoleon customer support with proof of purchase and detailed issue description. Repairs under warranty must use authorized parts to maintain coverage. The warranty ensures peace of mind, reflecting Napoleon’s commitment to quality and reliability, as certified by CSA and ANSI standards.

6.2. Replacement Parts and Dealer Information

For replacement parts, contact authorized Napoleon dealers to ensure genuine components. Only use parts approved by the manufacturer to maintain safety and warranty validity. Dealers can be located through Napoleon’s official website or by contacting their customer support at 1 (866) 820-8686. Proper installation of replacement parts must be performed by a qualified technician to avoid voiding the warranty. Visit www.napoleon.com for a comprehensive list of dealers and parts. Always verify the authenticity of parts to ensure compliance with CSA and ANSI standards, guaranteeing reliability and safety.

Discover the Napoleon Gas Fireplace Manual for troubleshooting, installation, and maintenance tips. Ensure optimal performance with our comprehensive guide.

Leave a Reply